大数据支持下产前超声筛查质量控制与漏诊风险评估研究
王晓嘉
作者信息
- 陕西中医药大学第二附属医院 陕西 咸阳 712000
摘要
目的:构建大数据驱动的产前超声筛查质量控制体系,建立漏诊风险评估模型,为提升产前超声筛查精准度、降低出生缺陷漏诊率提供技术支撑与实践方案。方法:回顾性收集多中心产前超声检查数据,包括超声影像资料、临床诊断信息、母体基本信息等多源数据,构建标准化大数据集。基于深度学习算法构建超声图像质量评估模型,整合多维度数据建立漏诊风险评估指标体系,采用随机森林与Logistic回归算法构建风险预测模型。通过精确率、召回率、平均精度、准确率及加权Kappa系数评估模型效能,采用Bootstrap法验证模型稳定性。结果:本研究构建的大数据集包含15 240例孕妇的38 620张超声图像及完整临床数据,其中异常病例1862例。基于YOLO V8的超声图像质量评估模型对标准切面识别准确率达96.8%,与专家评估一致性极强(加权Kappa=0.955);漏诊风险评估模型可有效识别高风险病例,预测敏感度为86.45%、特异度为88.01%,约登指数达74.46。大数据质量控制体系实施后,基层医院神经管缺陷检出率从51%提升至89%,区域整体漏诊率下降40%。结论:大数据技术可实现产前超声筛查的标准化质量控制,构建的漏诊风险评估模型具有良好的预测效能,能有效提升筛查质量,缩小不同层级医疗机构间的技术差距,对强化出生缺陷二级预防具有重要意义。
Research on Quality Control and Missed Diagnosis Risk Assessment in Prenatal Ultrasound Screening Supported by Big Data
Xiao-jia Wang
Author Information
- The Second Affiliated Hospital of Shaanxi University of Chinese Medicine, Xianyang 712000, Shanxi Province, China
Abstract
Objective: To establish a big data-driven quality control system for prenatal ultrasound screening and develop a risk assessment model for missed diagnoses, thereby providing technical support and practical solutions to improve the accuracy of prenatal ultrasound screening and reduce the rate of missed diagnoses of birth defects. Methods: Retrospective collection of multi-center prenatal ultrasound data, including ultrasound imaging, clinical diagnostic information, and maternal basic information, was conducted to build a standardized big data dataset. A deep learning-based model for assessing ultrasound image quality was constructed, and a multidimensional data-integrated missed diagnosis risk assessment indicator system was established. Random forest and logistic regression algorithms were employed to develop a risk prediction model.Model performance was evaluated using precision, recall, average precision, accuracy, and weighted Kappa coefficient,while stability was validated using the Bootstrap method. Results: The constructed big data dataset included 38,620 ultrasound images and complete clinical data from 15,240 pregnant women, with 1,862 abnormal cases. The YOLO V8-based ultrasound image quality assessment model achieved an accuracy of 96.8% in standard plane recognition, demonstrating strong agreement with expert evaluations (weighted Kappa = 0.955). The missed diagnosis risk assessment model effectively identified high-risk cases, with a sensitivity of 86.45%, specificity of 88.01%, and Youden index of 74.46. After implementing the big data quality control system, the detection rate of neural tube defects in primary hospitals increased from 51% to 89%,and the regional overall missed diagnosis rate decreased by 40%. Conclusion: Big data technology enables standardized quality control in prenatal ultrasound screening. The developed missed diagnosis risk assessment model demonstrates good predictive performance, effectively enhancing screening quality and narrowing technical disparities among healthcare institutions at different levels. This holds significant importance for strengthening secondary prevention of birth defects.