ICP-MS法测定土壤和沉积物中锡元素的研究

马玉凤 ,朱美洁 *,庄景宏 ,李师炜
作者信息
  1.  福建省环境监测中心站  福建 福州  350003

摘要

本文以电感耦合等离子体质谱仪为基础,结合三种预处理方法进行对比,建立了测定土壤和沉积物中锡元素浓度的分析方法。三种方法检出限分别为0.4 mg/kg、0.4 mg/kg和0.2 mg/kg,测定下限分别为1.6 mg/kg、1.6 mg/kg和0.8 mg/kg。其中,超级微波消解法在灵敏度与精密度方面表现最优。实验过程采用GSS/GSD系列有证标准物质进行验证,锡的标准值与测定值吻合度良好,相对误差主要集中在-10%~10%范围内,相对标准偏差低于6.5%;结果表明,结合微波消解与ICP-MS方法适用于土壤和沉积物中锡的测定。

Determination of Tin in Soil and Sediment by ICP-MS

Yu-feng Ma , Mei-jie Zhu *, Jing-hong Zhuang , Shi-wei Li
Author Information
  1.  Fujian Environmental Monitoring Central Station, Fuzhou 350003, Fujian Province, China

Abstract

This study established an analytical method for determining tin concentration in soil and sediment using inductively coupled plasma mass spectrometry (ICP-MS), comparing three pretreatment methods. The limits of detection for the three methods were 0.4 mg/kg, 0.4 mg/kg, and 0.2 mg/kg, with corresponding lower limits of quantification of 1.6 mg/kg,1.6 mg/kg, and 0.8 mg/kg, respectively. The ultra microwave digestion method demonstrated optimal performance in sensitivity and precision. Certified reference materials from the GSS/GSD series were employed for method validation. The measured values for tin showed good agreement with certified values, with relative errors primarily within the range of -10% to 10%, and relative standard deviations below 6.5%. The results indicate that the combination of microwave digestion and ICP-MS is suitable for the determination of tin in soil and sediment.